FLFailureLab.ENGENHARIA APLICADA
PTOpen tool
FAILURELAB • ENGINEERING KNOWLEDGE

ISO 17359:2018 — scope and application in failure analysis

General guidance for developing machine condition monitoring programmes.

Technical standard

Scope overview

General guidance for developing machine condition monitoring programmes.

Application in FailureLab

Supports measurement collection, comparison of operating conditions and trend analysis.

Limits of use

Does not by itself provide universal vibration, temperature or maintenance decision limits.

Consult original publication / catalog ↗

Educational overview of scope and intended application, not normative text or a clause-by-clause summary. Consult the applicable edition and your sector requirements.

Related methods

Trend / time seriesVisualize progression of a variable and optional reference limit.

Records citing this reference

Abrasive wearHard particles or asperities remove material from a contacting surface.Adhesive wearLocal junctions between sliding surfaces break and transfer material.Insufficient lubricationInadequate lubricant film promotes surface contact and increased friction.OverlubricationChurning or flow restriction can increase temperature and internal pressure.MisalignmentCoupled shafts have angular or parallel offsets that increase loads.UnbalanceMass distribution away from the rotation axis generates periodic centrifugal force.Mechanical loosenessLoss of stiffness at interfaces or fasteners changes dynamic response.Fretting wearSmall oscillatory interface displacements cause wear and oxidation.ResonanceExcitation near a natural frequency amplifies vibration response.Gear tooth fractureOne or more teeth lose structural integrity and load transmission.Belt slipFriction drive loses sufficient grip or tension.Mechanical fatigueCyclic stresses initiate and propagate cracks even below static strength.Ductile fracturePlastic deformation and void coalescence precede fracture.Brittle fractureA crack propagates rapidly with limited macroscopic plastic deformation.Uniform corrosionChemical or electrochemical reactions reduce thickness broadly.Pitting corrosionLocalized attack forms cavities that may penetrate the section.Galvanic corrosionElectrically connected metals in an electrolyte may undergo preferential attack.Stress corrosion crackingA specific environment, susceptible material and tensile stress promote cracking.CreepTime-dependent deformation under significant stress and temperature.ErosionParticle, droplet or flow impact removes material.Elastomer degradationHeat, incompatible fluid, ozone or aging change polymer properties.CavitationVapor forms at low local pressure and collapses in higher-pressure regions.Fluid aerationAir enters or remains dispersed in a liquid, changing compressibility and flow.External leakageFluid crosses a boundary intended to contain it.Internal leakageFluid passes between chambers or circuits, reducing performance without necessarily external loss.Filter blockageAccumulated solids increase pressure drop and restrict flow.Water hammerRapid fluid velocity change creates a transient pressure wave.Stuck valveMoving element cannot travel through the required range.Insulation degradationThermal aging, moisture, contamination or electrical stress reduce dielectric properties.Open circuitA connection or conductor loses electrical continuity.Short circuitAn unintended low-impedance path connects different potentials.High contact resistanceA degraded electrical interface dissipates extra heat under current.Electrical overloadCurrent or power exceeds capacity applicable to the operating duty.Phase imbalancePhase differences can increase losses and machine heating.Battery capacity lossElectrochemical aging or service conditions reduce usable energy.Heat exchanger foulingDeposits increase thermal or hydraulic resistance.Refrigerant leakageThe circuit loses inventory through a non-tight boundary.Liquid refrigerant floodbackLiquid refrigerant reaches suction under conditions unsuitable for the compressor.Insufficient airflowDelivered airflow does not meet thermal or ventilation function.Evaporator icingSurface temperature and moisture allow ice formation.Sensor driftIndication progressively deviates from the reference value.Signal lossA channel stops transmitting usable information.Control loop oscillationProcess-control dynamics generate persistent variation.Rebar corrosionLoss of passivity and electrolyte presence promote embedded steel corrosion.Structural crackingA discontinuity forms or propagates in structural material.Differential settlementUnequal support displacement creates incompatible deformation.Water ingressWater crosses envelope, joints or waterproofing interfaces.Pavement ravelingLoss of particles or surface bonding deteriorates the wearing course.
Educational support. Actual investigations require evidence, risk assessment, applicable criteria and validation by responsible professionals. References do not imply standards compliance.

Turn knowledge into investigation

Use the methods in the software, organize evidence and export a report. Free, no sign-up.

Open FailureLab