FLFailureLab.ENGENHARIA APLICADA
PTOpen tool
FAILURELAB • ENGINEERING KNOWLEDGE

Failures in Other / unlisted equipment

Components, related failure modes and investigation paths for Other / unlisted equipment.

Other / unlisted equipment
Original technical diagram · Educational reference, not event evidence.

Components and investigation boundary

Describe the asset, components and function in identification. The entire library is available.

How to start the investigation

Define required function, capacity, normal conditions, identification, load and intervention history. Compare observed with expected performance and record each source. The list below helps form hypotheses; it neither limits the investigation nor indicates failure frequency.

Explore in software

Modes, mechanisms and conditions to investigate

Abrasive wearDirectional grooves, debris and dimensional change.Adhesive wearSmearing, transferred material and polished or torn regions.Rolling contact fatiguePits, spalling and vibration at component-related frequencies.False brinellingRegularly spaced marks, possible oxidized debris.Insufficient lubricationTemperature, wear, noise and lubricant changes.OverlubricationHeating after regreasing, excessive purge, leakage.MisalignmentAxial/radial vibration, coupling wear, heating.UnbalanceRadial vibration often dominant at 1× shaft speed.Mechanical loosenessHarmonics, impacts, relative motion marks.Fretting wearRed or dark debris, marks at fits and interfaces.ResonanceAmplitude peak within a speed range, phase change.Bearing seizureBlocked rotation, heating, smearing and possible trip.Gear tooth fractureBroken tooth, fragments, impacts and meshing change.Belt slipLower-than-expected speed, heat, dust, noise.Mechanical fatigueLocalized origin, possible propagation zone and final fracture.Ductile fractureNecking or deformation; dimples in specialized examination.Brittle fractureLow deformation, possible cleavage; visual appearance is not conclusive.Uniform corrosionDistributed wall loss and corrosion products.Pitting corrosionIsolated pits, perforations or deposits.Galvanic corrosionAttack concentrated on one metal near joints.Stress corrosion crackingBranched or localized cracks; appearance depends on the system.CreepElongation, bulging and cracks after extended service.ErosionLocalized material loss oriented with flow.Elastomer degradationHardening, softening, swelling, cracking.CavitationNoise, vibration, localized erosion, possible head loss.Fluid aerationFoam, irregular response, noise and possible pressure loss.External leakageWetness, volume loss, residue or falling level.Internal leakageActuator drift, pressure drop, heating.Filter blockageHigh differential pressure and reduced flow.Water hammerTransient spikes, noise, pipe movement or damage.Stuck valvePosition-command mismatch, improper flow, high torque.Insulation degradationLeakage, trips, tracking or changed test results.Open circuitNo current, lost function or phase.Short circuitProtective trip, thermal damage or arc marks.High contact resistanceLocalized hot spot, discoloration and voltage drop.Electrical overloadDistributed heating, thermal trip and reduced life.Phase imbalanceUnequal currents or voltages, abnormal temperature.Electrical erosion in bearingCraters, fluting pattern or darkened lubricant.Battery capacity lossReduced runtime, internal resistance or cell imbalance.Heat exchanger foulingHigh approach temperature, pressure drop, increased consumption.Refrigerant leakageReduced capacity, altered pressure and superheat conditions.Liquid refrigerant floodbackLow superheat, oil foaming and instability.Insufficient airflowTemperature difference, differential pressure, poor comfort.Evaporator icingVisible ice, reduced flow and unstable capacity.Sensor driftIncreasing difference against independent comparison, biased control.Signal lossInvalid value, communication alarms, frozen state.Control loop oscillationVariable oscillation, repeated actuation and actuator wear.Configuration errorBehavior after change, inconsistent alarms or unexpected setpoints.Rebar corrosionStaining, longitudinal cracking and possible spalling.Structural crackingCrack width, orientation, displacement or progression.Differential settlementDiagonal cracks, unevenness and door interference.Water ingressStaining, moisture, efflorescence and dripping.Pavement ravelingLoose material, changed texture and progressive aggregate loss.Inadequate procedureConflicting versions, ambiguous steps, practice deviations.Communication breakdownUncommunicated change, incomplete records, different interpretations.Insufficient change managementFailure after intervention, undocumented configuration or missing test.Missing or degraded barrierUnnoticed alarm, unavailable protection, missing verification.Inadequate maintenance planningCritical backlog, omitted task or recurring intervention without diagnosis.Insufficient competence or supportExecution difficulty, inaccessible instructions, reliance on improvisation.Incompatible part or materialFailure after replacement, dimensional difference or abnormal performance.
Educational support. Actual investigations require evidence, risk assessment, applicable criteria and validation by responsible professionals. References do not imply standards compliance.

Turn knowledge into investigation

Use the methods in the software, organize evidence and export a report. Free, no sign-up.

Open FailureLab