Failures in Hydraulic system
Components, related failure modes and investigation paths for Hydraulic system.

Components and investigation boundary
Pump, reservoir, filter, valve, actuator
How to start the investigation
Define required function, capacity, normal conditions, identification, load and intervention history. Compare observed with expected performance and record each source. The list below helps form hypotheses; it neither limits the investigation nor indicates failure frequency.
Modes, mechanisms and conditions to investigate
CavitationNoise, vibration, localized erosion, possible head loss.→Fluid aerationFoam, irregular response, noise and possible pressure loss.→External leakageWetness, volume loss, residue or falling level.→Internal leakageActuator drift, pressure drop, heating.→Filter blockageHigh differential pressure and reduced flow.→Stuck valvePosition-command mismatch, improper flow, high torque.→
Educational support. Actual investigations require evidence, risk assessment, applicable criteria and validation by responsible professionals. References do not imply standards compliance.
Turn knowledge into investigation
Use the methods in the software, organize evidence and export a report. Free, no sign-up.