Pump with performance loss — training case

Centrifugal pump: vibration and noise after a tank level decrease.

Cavitation
AI-generated illustration · Educational reference, not event evidence.

Fictional scenario

Centrifugal pump: vibration and noise after a tank level decrease.

Suggested approach

Timeline + hypothesis matrix + 5 Whys; compare absolute pressure and curve.

Initial hypothesis to test

Vapor forms at low local pressure and collapses in higher-pressure regions.

Data to seek

Check absolute suction pressure, temperature, available/required NPSH and OEM curve; distinguish aeration.

Discussion and next steps

What facts are known? Which alternatives are plausible? What test would distinguish hypotheses? Record answers before proposing actions. The exercise does not contain enough data to declare a confirmed cause.

CavitationNoise, vibration, localized erosion, possible head loss.Method guideChoose and combine tools.
Open complete example in software
Educational support. Actual investigations require evidence, risk assessment, applicable criteria and validation by responsible professionals. References do not imply standards compliance.