FLFailureLab.ENGENHARIA APLICADA
PTOpen tool
FAILURELAB • ENGINEERING KNOWLEDGE

FMEA / prioritization — how to use, example and results

Relate function, mode, effect, cause and controls; prioritize actions.

RPN by mode (S×O×D)Leak96Wear72Seizure72
Illustrative example · fictional data

When to use

To anticipate failures and review controls after an event; not a replacement for retrospective investigation.

Required inputs

Function, mode, effect, potential cause, controls, S/O/D criteria, action and owner.

How to apply in FailureLab

Define local scales before scoring; describe function and effects; assess severity, occurrence and detection difficulty; review actions.

What the tool delivers

Editable table and RPN prioritization = S × O × D. Consider severity regardless of RPN.

Worked example (fictional)

Pump seal: S=8, O=3, D=4; RPN=96. Actions should address the demonstrated mechanism, not just lower a score.

Cautions and limitations

RPN is an ordinal simplified ranking, not probability or monetary risk; no automatic IEC 60812 compliance.

Tool fields

Try this method with an example

Supporting references

Educational support. Actual investigations require evidence, risk assessment, applicable criteria and validation by responsible professionals. References do not imply standards compliance.

Turn knowledge into investigation

Use the methods in the software, organize evidence and export a report. Free, no sign-up.

Open FailureLab